L0LW0101 Pempek OBP Solenoid Module Ex ib Intrinsically Safe I/O Type A
L0LW5301 Pempek OBP Solenoid Module Ex ib Intrinsically Safe I/O Type B
The Pempek OBP Mining PLC I.S. I/O Module provides intrinsically safe (Group I Ex ib) input and output resources in a single, compact unit.
A unique fibre-optic communications interface means that the module and dedicated I.S power supply can be conveniently segregated into its isolated zone.
The fibre-optic link between the module and an Pempek OBP processor module provides real-time control and monitoring of all I/O points.
This solution is ideal for mobile mining equipment where limited installation space must be achieved.
Uniquely Keyed Type Connectors to prevent incorrect machine installation.
The module is Dual Pempek OBP Type which complies with AS/NZS 4240 standard.
As per standard, every output includes two switches A&B in series with monitoring feedbacks from both.
Extra safety is achieved by using two potted boards each includes main and watchdog processors monitoring the correctness of executed main software code.
L0LW
L0LW0101
Module Type: Intrinsically Safe Input / Output with Display
Supply: 12VDC (+/- 10%) / 20 Watts (Max) from Approved I.S. Power Supply
Data Communications: CAN interface over Pempek OBP Fibre
Operating Temperature: -20°C to +85°C all industrial components
Inputs 1: 24 x I.S. Digital Inputs (12VDC)
Inputs 2: 16 x I.S. Analog Inputs (4-20 mA)
Inputs 3: 16 x I.S. Namur Inputs
Outputs: 24 x I.S. 12VDC On/Off Outputs (1A Maximum for each Output)
Connector 1: Pempek OBP Fibre
Connector 2: Pempek OBP A18 (12VDC I.S. Supply and Solenoid Outputs)
Connector 3: Pempek OBP A19 (12VDC I.S. Supply and Namur Inputs)
Connector 4: Pempek OBP A20 (Digital Inputs and Analog Inputs)
Heavy Duty Enclosure
Electroless Nickel Plated
Rugged Construction
Mass
6.5kg (14.3lb)
L0LW5301
Module Type: Intrinsically Safe Input / Output with Display
Supply: 12VDC (+/- 10%) / 20 Watts (Max) from Approved I.S. Power Supply
Data Communications: CAN interface over Pempek OBP Fibre
Operating Temperature: -20°C to +85°C all industrial components
Inputs 1: 24 x I.S. Digital Inputs (12VDC)
Inputs 2: 16 x I.S. Analog Inputs (4-20 mA)
Inputs 3: 16 x I.S. Namur Inputs
Outputs: 24 x I.S. 12VDC On/Off Outputs (1A Maximum for each Output)
Connector 1: Pempek OBP Fibre
Connector 2: Pempek OBP B18 (12VDC I.S. Supply and Solenoid Outputs)
Connector 3: Pempek OBP B19 (12VDC I.S. Supply and Namur Inputs)
Connector 4: Pempek OBP B20 (Digital Inputs and Analog Inputs)
Heavy Duty Enclosure
Electroless Nickel Plated
Rugged Construction
Mass
6.5kg (14.3lb)