L0MD0101 Pempek OBP Bolter Solenoid Module Ex ib Intrinsically Safe I/O Type A

L0MD0201 Pempek OBP Bolter Solenoid Module Ex ib Intrinsically Safe I/O Type B

The Pempek OBP Mining PLC I.S. I/O Solenoid Driver Module provides intrinsically safe (Group I Ex ib) input and output resources in a single, compact unit.

A unique fibre-optic communications interface means that the module, and dedicated IS power supply, can be conveniently segregated into its, isolated zone.

The fibre-optic link between the module and an Pempek OBP processor module provides real-time control and monitoring of all I/O points.

This solution is ideal for mobile mining equipment where limited installation space must be achieved.

Uniquely keyed typed connectors to prevent incorrect machine installation.

The module is Dual Pempek OBP Type which complies with AS/NZS 4240 standard. 

As per standard, every output includes two switches A&B in series with monitoring feedbacks from both. 

Extra safety is achieved by using two potted boards each includes main and watchdog processors monitoring the correctness of executed main software code. 

L0MD
Specifications

 Module Type: Intrinsically Safe Input / Output with Display 

Supply: 12VDC (+/- 10%) / 20 Watts (Max) from Approved I.S. Power Supply 

Data Communications: CAN interface over Pempek OBP Fibre 

Operating Temperature: -20°C to +85°C all industrial components 

Inputs 1: 8 x I.S. Digital Inputs (12VDC) 

Inputs 2: 4 x I.S. Analog Inputs (4-20 mA) 

Inputs 3: 4 x I.S. Frequency Counter Inputs (Namur Type, 5 kHz Max) 

Inputs 4: 2 x I.S. Resolver Sensor Inputs (Industry Standard Siemens or Litton) 

Inputs 5: 28 x Proximity Switch Inputs (Namur Type) 

Outputs: 24 x I.S. 12VDC On/Off Outputs (Max 1A for each Output) 

Connector 1: CAN Interface over Pempek OBP Fibre 

LØMDØ1Ø1

Connector 2: Pempek OBP A18 (12VDC I.S. Supply and Solenoid Outputs) 

Connector 3: Pempek OBP A12 (Digital Inputs, Analog Inputs, Frequency Counter Inputs, Resolver Sensors and Proximity Switch Inputs) 

Connector 4: Pempek OBP A15 (12VDC I.S. Supply and Proximity Switch Inputs) 

LØMDØ2Ø1

Connector 2: Pempek OBP B18 (12VDC I.S. Supply and Solenoid Outputs)

Connector 3: Pempek OBP B12 (Digital Inputs, Analog Inputs, Frequency Counter Inputs, Resolver Sensors and Proximity Switch Inputs)

Connector 4: Pempek OBP B15 (12VDC I.S. Supply and Proximity Switch Inputs)

Heavy Duty Enclosure 

• Electroless Nickel Plated 

• Rugged Construction 

Mass 

• 6.5kg (14.3lb) 

Line Drawing
Display Diagnostics 
Fibre Optic Patch Cables