Hydraulic Manifold 5 Shooter is a self-contained electronic-over-hydraulic control manifold integrated into a flameproof-certified (Ex d) protective enclosure.

L0W0
Description

The manifold is controlled and monitored from a host control system (PLC) via a single, industry-standard CAN field bus cable and 24-volt power source.

The manifold provides the following hydraulic control and monitoring features:

  • Five (5) Spool Valves (150 litres/minute, 3-position, proportional, open-centre)
  • Five (5) Fixed 14-bar compensator to regulate flow for each spool valve
    Three (3) Pilot Pressure Signal Output Valves
  • One (1) Automatic spool flow safety isolation valve (internally managed)
  • One (1) General Purpose Pressure Monitoring Port
  • One (1) Internal hydraulic oil temperature sensorThe manifold also provides built-in spool position monitoring and stuck-spool safety protection.This version of the HBox 5 is configured for Russian language.